How to size an air conditioner
Sizing & LoadWhy square-foot rules of thumb oversize, and what to measure instead.
9 min
Dehumidifier sizing in two answers: the minimum pints per day ENERGY STAR recommends for your space and how damp it is, and what an old pre-2019 rating means on today's labels.
What to work out: Size for a space
Pre-filled with a 1,000 ft² basement that smells damp all the time.
Consistently feels and smells damp; damp spots on walls and floors
25–40
Minimum capacity on the current DOE rating
Dehumidifier size is capacity: the pints of water a unit removes in 24 hours at fixed test conditions. What you need depends on two things — how big the space is and how wet it is before you start. ENERGY STAR's chart puts the two together for portable units:
| Condition without dehumidification | Under 2,000 ft² | Over 2,000 ft² |
|---|---|---|
| Slightly to moderately damp — feels damp, with a musty odour that may be intermittent. 50–75% RH. | 20–30 | 30+ |
| Very damp — consistently feels and smells damp; damp spots on walls and floors. 75–90% RH. | 25–40 | 40+ |
| Wet — walls or floor sweat, or seepage; high loads such as laundry drying. 90–100% RH. | 30–50 | 50+ |
The figures are minimums, and the rule beside them is blunt: it's better to oversize than undersize; if replacing a unit, judge by how much water you empty each day. A bigger unit reaches the humidistat setting sooner and cycles off; a small one on a wet basement runs flat out and never gets there.
Sources: EPA ENERGY STAR, Dehumidifiers — buying guidance (read 2026-10-18)
DOE dehumidifier standards based on Integrated Energy Factor (IEF) took effect in June 2019. The capacity test moved with them: portable units were previously tested at 80 °F; the new procedure tests at 65 °F, so the same unit will likely report a smaller capacity. Cooler air holds less water, so a unit that was a "70-pint" on the old test is rated lower now without removing any less in your basement. Under the current federal procedure, portable dehumidifiers are tested at 65 ± 2.0 °F dry bulb and 60 ± 2% relative humidity; whole-home dehumidifiers are tested at 73 ± 2.0 °F dry bulb and 60 ± 2% relative humidity.
| Portable, old | Portable, now | Whole-home, old | Whole-home, now |
|---|---|---|---|
| 30 | 20 | 80 | 70 |
| 40 | 25 | 100 | 85 |
| 50 | 30 | 120 | 100 |
| 55 | 30–35 | 140 | 115 |
| 60 | 35 | 160 | 135 |
| 70 | 40–45 | 200 | 170 |
| 90 | 55 | — | — |
A rough correlation between old and new (2020) capacity ratings; the actual change for specific models will vary. Replacing a unit? The water you empty each day is a better guide than either label.
Sources: EPA ENERGY STAR, Dehumidifier Testing and Capacity (read 2026-10-18) · 10 CFR 430, subpart B, appendix X1 (eCFR), Table 1 to paragraph 4.1.1 (read 2026-10-18)
Whole-home units carry significant benefits for relatively well sealed homes with central air that see humidity above 55% consistently throughout the house. A whole-home unit ties into the ductwork, drains to a floor drain or condensate pump, and has to be sized and installed by a professional — ENERGY STAR publishes no chart for it. Portables win for a single basement, a crawlspace or one problem room.
Ventilation adds moisture too
A house that brings in outdoor air all summer brings in its humidity as well. An ERV moves some of that moisture back out with the exhaust air; an HRV does not — see ERV vs HRV before adding a dehumidifier to a ventilated house.
On a summer humidity problem the first suspect is often the AC itself. ENERGY STAR's warning about room units applies to central systems too: an oversized unit cools the room before it has a chance to remove the humidity, leaving the room damp and clammy. A system that short-cycles never runs long enough for its coil to pull water out. Run the house through the AC unit size calculator and read how to size an AC unit before buying a dehumidifier to cover for an oversized condenser. If one damp room has no supply register at all, ENERGY STAR suggests adding one so the AC can dry it.
Sources: EPA ENERGY STAR, How To Choose the Right Sized Window AC (2024-02-02) (read 2026-10-18)
The optimum relative humidity for a building is generally between 30% and 50%; above it may promote mold growth. In colder climates during the heating season, 30% to 40% to prevent window condensation. Every ENERGY STAR model has a built-in humidistat, and an ENERGY STAR certified dehumidifier removes the same moisture as a similar conventional unit with 20% less energy.
A tune-up that cleans the coil and checks the condensate drain belongs on the maintenance list as well: a central system with a dirty coil dries the air less than it should.
Sources: EPA ENERGY STAR, Dehumidifiers — buying guidance (read 2026-10-18)
Why square-foot rules of thumb oversize, and what to measure instead.
9 min
Heat recovery with and without moisture transfer, by climate zone.
% recovery
Tonnage for a whole house, with the oversizing check most rules of thumb skip.
tons · sq ft
Same cooling cycle plus a reversing valve: SEER2 floors, indoor pairing and dual fuel.
SEER2 vs SEER2
More in Cooling — 6 tools, 5 guides, on SetpointKit. Or browse every HVAC calculator.