Mini split sizing calculator

A ductless head only serves the room it is mounted in. Size each zone on its own, then check that the heads added together have not quietly doubled the house load.

Head sizes

6–36k BTU/h

The stocked ladder

Oversize flag

1.3× load

Heads against calculated load

SEER2 minimum

13.4SEER2

Split systems, national

HSPF2 minimum

7.5HSPF2

Split heat pumps

Thermal-toned ductless head cooling a room
One head, one room: the air it throws does not turn corners.

Why ductless sizing is different

A ducted system distributes one capacity around a house. A ductless system parks a fixed capacity in one room and hopes the doorway does the rest. That changes the sizing rule completely: you size to the room, not to the floor area of the house, and a sunroom with three glass walls needs several times the head that its square footage suggests.

The exposure column is doing that work. "Sunroom" multiplies the cooling load by 1.6 because glass on three sides is not a wall. A north-facing interior office gets 0.9.

The multi-zone trap

Heads add up faster than the load does

Head sizes come in a coarse ladder — 6k, 9k, 12k, 15k, 18k. Round every room up to the next rung and a house with a 30,000 BTU/h load ends up with 42,000 BTU/h of heads. The outdoor unit modulates, but each head has a minimum output, and below it the system short-cycles that zone: cold blasts, poor dehumidification, a compressor that never settles.

The oversize ratio in the panel is the check. Under about 1.3 is fine. Above 1.5, combine two small adjacent rooms onto one head or move to a ducted mini-split air handler for that part of the house.

How many heads a house needs

Typical head counts by layout
LayoutHeadsWhy
Studio or open one-bedroom1One space, doors open, air moves
Open-plan main floor + 2 bedrooms3Bedroom doors close at night
Two-storey, 4 bedrooms5–6Every closed room needs its own
Addition or garage conversion1The classic single-zone retrofit
Whole house, ducts already there0A ducted system is cheaper per ton

If the answer is five or six heads, price a ducted heat pump against it before you commit — the ductless against central comparison works through where the crossover sits.

Heating mode is the harder case

Switch the control to heating and the numbers move: in zone 5 the heating load per square foot is roughly double the cooling load. A head sized for a bedroom's cooling will not hold that bedroom in January. In a cold climate, size the heads on the heating column and accept the cooling oversize — inverter equipment turns down far better than it turns up. The heat pump sizing calculator finds the balance point for the outdoor unit.

Sources: 10 CFR 430.32(c)(5)(ii) (read 2026-09-04)